The cable

PAROL6 and PAR6 gripper cables are not interchangeable
Figure 4.3: PAROL6 and PAR6 gripper cables are not interchangeable.

One cable with an M8 4-pin connector powers the gripper and carries its CAN bus. The robot end differs from robot to robot.

PAROL6 and PAR6 cables are different

The two robots put the four signals on different pins of their gripper port. The PAROL6 cable in a PAR6, or the other way round, puts 24 V on the CAN bus and destroys the gripper's driver. Use the cable sold for your robot, and check a self-made cable pin by pin.

The cables from the shop

Robot Cable
PAROL6 PAROL6 gripper cable
PAR6 the PAR6 gripper cable, coming to the shop

Making your own

For a bench setup, another robot, or a replacement, the cable is four wires between an M8 4-pin female connector at the gripper and whatever the other end needs:

Part Quantity BOM
26 AWG 4-wire twisted-pair cable, 0.15 mm², shielded about 0.4 m cable
M8 4-pin female cable connector (the gripper has the male) 1 connector
M8 4-pin male cable connector, for a robot with an M8 port 1 the same listing

The M8 male connector The M8 female connector A finished cable

Wire it as the diagram for your robot shows. Pin 1 to 4 are the numbers moulded into the M8 connectors; the colours are those of the cable in the BOM.

The PAROL6 cable: the pins are crossed between the two ends
Figure 4.4: The PAROL6 cable: the pins are crossed between the two ends.

The PAR6 cable: pin to pin
Figure 4.5: The PAR6 cable: pin to pin.

Connect the gripper's 24V and GND to a 24 V supply and its CANH and CANL to your CAN interface; on a PC that is the CANvas adapter's CAN terminals. Connector and pinout shows which pin of the gripper's connector is which signal. Twist the CAN pair, keep the cable short at 1 Mbit/s, and terminate the bus at both ends (CAN termination).

Connect the shield at one end only. Check continuity and the absence of shorts between all four pins before the first power-up.

Handling

Plug and unplug with the supply off. Route the cable along the robot with enough slack for the wrist's full motion, and keep it away from the jaws' travel.