Step 6: System check¶
Reboot the Pi. The service starts the runtime, and the real-time loop writes its start-up into logs/RTI.log in the
runtime's folder. Do the first start with the arm resting safely and nothing in its reach, and check that the
E-stop stops the robot before you enable motion.
Check
logs/RTI.log has these lines from the start:
real-time setup OK, notDEGRADEDorFAILED: the loop runs with real-time priority on its own core;memory locked: its memory cannot be swapped out;interrupt threads ... on core 2 alone: the CAN chip's interrupts have a core to themselves;- after
STARTUP SELFCHECK,CAN scan OKwith every drive present, andPASSED — all checks OK.
Then home the arm (Homing). If a line is missing or the self-check fails,
bash scripts/setup_system.sh --check (Step 4) names what is not set up. A drive missing from
the CAN scan does not answer on the bus: check its cable, its supply and its address
(CAN bus and drive addresses).
Found a mistake on this page? Edit it on GitHub · Report it · Get help