Step 3: Installing the runtime

Not yet repeated on a clean machine

The installation follows how the reference robot was set up. A package the robot needs may still be missing from requirements.txt; Step 4's check imports the runtime's main packages and names any that fail. The faults known so far: Known issues.

1. Python 3.11 as python3

Ubuntu 24.04 ships Python 3.12 as python3. The reference robot runs 3.11, and every version pinned in requirements.txt was tested on it. The installer takes whatever python3 is and accepts 3.12 without a word, so make 3.11 the python3 first. It comes from the deadsnakes package archive:

sudo add-apt-repository ppa:deadsnakes/ppa
sudo apt-get install -y python3.11 python3.11-venv python3.11-dev
sudo update-alternatives --install /usr/bin/python3 python3 /usr/bin/python3.11 1
sudo update-alternatives --set python3 /usr/bin/python3.11

2. The runtime

The reference robot keeps the runtime in ~/Desktop/RCB-Runtime. Any folder works: Step 4 sets the service up for the folder you choose.

cd ~/Desktop
git clone https://github.com/Source-Robotics/RCB-Runtime.git
cd RCB-Runtime
git checkout v3.0.1
./scripts/install.sh

git checkout picks the release these pages describe. The installer asks before it installs packages with apt, makes the environment .venv from requirements.txt, creates the folders logs/ and temp_data/, and runs the system check scripts/check_system.py. It does not set up the service; Step 4 does.

The robot runs on .venv, and so do the tests and the tools. To see its packages, use .venv/bin/python -m pip list; a plain python3 -m pip list shows the system's packages, which the robot does not use.

Check

python3 --version prints Python 3.11, and the installer ends with Install finished. In its system check, the Python line and every Import line read OK. Two kinds of line may still be wrong, and are put right later: the UART, I2C device, GPIO chip and real-time priority lines read WARN until Step 4 gives your user those rights, and CAN can0 up can fail until the runtime starts and brings the bus up (Step 6).


Found a mistake on this page? Edit it on GitHub · Report it · Get help