Skip to content

read_drive_parameters

Runs at once Any mode Open to every client

Read every parameter that the drives hold now. The robot asks each drive for its parameters (about 90 each: gains and limits, the motor model, the control loops, the watchdog, the build and board ids) one at a time, paced between its regular status requests, so its control loop does not slow down. All drives take about 5 s, one drive under 1 s. A new read replaces one that is still running. It moves nothing and changes nothing; it works in any mode. Read the values with get_drive_parameters().

Syntax

robot.read_drive_parameters(drive=None, wait=None)

Arguments

Name Type Default Description
drive int | None None The drive to read: 1 to the number of joints for a joint, one more for a CAN gripper. None reads every drive.
wait bool | None None Wait until the read has finished, up to 30 s. None follows the client's sync setting.

Returns

Nothing.

Examples

robot.read_drive_parameters(wait=True)
robot.read_drive_parameters(6, wait=True)
Usage restrictions 3 codes

This command runs at once; it is not queued. The robot accepts it in any mode and state, from every client.

It answers with one of these codes when it does not carry the command out:

  • [6003] Invalid arguments — drive is not one of this robot's drives
  • [6025] RTI not running or not answering — rTI did not answer within 1 s: it is not running or not responding. The command may still have taken effect
  • [6026] Refused by RTI — rTI refused it: no such drive. The message says why

In Python, a code above raises CommandRejected; its number is the code. The call raises:

  • CommandRejected: The robot refused it: no such drive. Or RTI refused it or did not answer within 1 s (Errors:).
  • RobotTimeout: The robot did not answer within 5 s, or, with wait, the read had not finished after 30 s.
  • RobotConnectionError: The client is not connected.

If the connection drops while the call waits for the robot's answer, it raises CommandRejected with the code CONNECTION_LOST (DISCONNECTED after disconnect()); while it waits for the robot's status, RobotConnectionError.

Like every immediate command, it also answers BAD_ARGS when a raw client sends a value the robot cannot read at all, and INTERNAL when it fails inside the robot.

Protocol

A client that does not use robotclient sends this over the TCP command protocol (port 29000) for the example above:

{"id": "c1", "cmd": "read_drive_parameters", "args": []}

See also