By symptom. The error flags and what clears them are in Errors and recovery; the faults of the firmware that are known and not yet fixed, with what to do until they are, in Known issues.

The motor does not move

flowchart TD
    A([The motor does not move]) --> B{Does the driver answer?}
    B -- no --> C[The supply and its polarity, the LED;<br>UART: the baud rate, TX and RX;<br>CAN: the node ID, 1 Mbit/s, the termination]
    B -- yes --> D{Calibrated?}
    D -- no --> E[#Cal and #Save]
    D -- yes --> F{An error active? The LED on steadily}
    F -- yes --> G[#Error names it: fix the cause, then #Clear]
    F -- no --> H{A current limit above 0?}
    H -- no --> I[#Ilim to the motor's rated current, #Save]
    H -- yes --> J[Command a setpoint in a closed-loop mode;<br>#Mode and #Info show the state]

The driver does not answer

Symptom Check
No LED the supply, DC+ and DC−, the power cable's orientation. If the cable was the wrong way round the driver is destroyed
LED on, nothing on the terminal 256000 baud; TX to RX and RX to TX; the adapter's port; 3.3 V adapter; the line ending CR+LF
LED on, nothing on CAN the node ID; 1 Mbit/s on the adapter; termination (about 60 Ω across CAN H and CAN L with everything unpowered); the CAN cable's orientation
Unknown command the name's spelling and case: #Kpiq, not #kpiq
the LED is off and nothing works after a firmware update the bootloader has no valid firmware: flash again, see Updating through the bootloader

Motor GUI

Symptom Check
the browser offers no port a Chromium-based browser (Chrome, Edge, Brave, Opera); Firefox and Safari have no Web Serial
the port is listed but will not open another program holds it: a terminal, PlatformIO's monitor, the Arduino serial monitor
the port opens, nothing appears the driver's power; TX and RX crossed on a non-Source adapter; the baud rate on a non-Source adapter (256000)
No connection on CAN the CANvas adapter's port; the bus termination; the node ID of the driver; 1 Mbit/s
the calibration does not start calibration runs over the serial connection only, not over CAN
Unsaved changes after a power cycle the settings were not saved to the driver; Save writes them
the firmware update finds no bootloader power-cycle the driver while the GUI scans, to catch the bootloader's 2 s window. A driver with firmware 101 or older has no bootloader (one that reports 101 may have it: Drivers that report 101): Installing the bootloader on an older board

Calibration

The messages and their causes are in Calibration. The ones that come back most:

Symptom Cause
Magnet test: Failed magnet too far, axially magnetised, or missing
the motor wobbles left and right during calibration one phase is not connected
Open loop: Failed the motor did not turn: a phase open, the open-loop voltage (#Openv) too low for the motor
Commutation/alignment check failed! the motor did not respond to the commutation check: a phase open, #Iqoffset too low, a magnet that slips
calibration succeeds, the motor then runs badly or in the wrong direction the magnet slipped on the shaft; glue it and calibrate again
calibration succeeds but the LED stays on and #Error shows nothing #Info shows -1, a value from an older release (The check at power-up): #Default, calibrate again

The motor

Symptom Cause
crunching or whining at speed the current limit or the current loop gains too high; lower #Ilim, lower #Cbw and calibrate again, or lower #Kpiq
humming, oscillating at rest #Kpv or #Kpp too high; see Current limit and loop tuning
weak torque #Ilim low; the supply's current limit; a calibration run at a low supply voltage (the constants are off)
the motor is hot lower #Ilim, enable the thermistor; a gimbal motor held against a load at its current limit heats quickly
it stops with a Vbus error when decelerating the supply cannot absorb the returned energy; a different supply, or a brake resistor
it stops with a velocity error the measured speed passed the fixed limit of 20,000,000 ticks/s: an encoder fault or a slipping magnet, rarely a real runaway; #Vlimit does not change it
it falls behind under a load the torque limit: raise #Ilim within the motor's rating, or a bigger motor
it holds position with a sawtooth noise the position loop gain; the magnet distance

Low-quality motors

Motors with visibly bad windings, an uneven back-EMF or a resistance that differs between the phases calibrate poorly and run rough. The tested motors are known good.

The magnet and the encoder

  • The distance is 1 mm. "Magnet Good" from the magnet test does not mean the distance is right, only that the field is strong enough.
  • A magnet touching the chip can destroy the microcontroller; a magnet too far gives a noisy, wrong position.
  • The magnet must be diametrically magnetised and centred on the shaft.

The driver gets hot or shuts down

The MOSFET driver stage shuts down on its own overtemperature or overcurrent and reports a driver error. Lower the current limit, give the board airflow, check the motor leads for a short. Near 2.8 A the driver needs cooling.

After a firmware update

#Info shows the new release. If the values look wrong or the LED stays on: #Default, #Cal, #Save. A release note says when an update clears the calibration.

Getting help

Support says where to ask and what to include; #Info's output is the first thing.