Skip to content

Troubleshooting

By symptom. The error flags and what clears them are in Errors and recovery; the faults of the firmware that are known and not yet fixed, with what to do until they are, in Known issues.

The motor does not move

flowchart TD
    A([The motor does not move]) --> B{Does the driver answer?}
    B -- no --> C[The supply and its polarity, the LED;<br>UART: the baud rate, TX and RX;<br>CAN: the node ID, 1 Mbit/s, the termination]
    B -- yes --> D{Calibrated?}
    D -- no --> E[Enter the motor parameters, then #Cal and #Save]
    D -- yes --> F{An error active? The LED on steadily}
    F -- yes --> G[#Error names it: fix the cause, then #Clear]
    F -- no --> H{A current limit above 0?}
    H -- no --> I[#Ilim to the stepper's rated current, #Save]
    H -- yes --> J[Command a setpoint in a closed-loop mode;<br>#Mode and #Info show the state]

The driver does not answer

Symptom Check
No LED the supply, DC+ and DC−, the power cable's orientation. If the cable was the wrong way round the driver is destroyed
LED on, nothing on the terminal 256000 baud; TX to RX and RX to TX; the adapter's port; 3.3 V adapter; the line ending CR+LF
LED on, nothing on CAN the node ID; 1 Mbit/s on the adapter; termination (about 60 Ω across CAN H and CAN L with everything unpowered); the CAN cable's orientation
Unknown command the name's spelling and case: #Kpiq, not #kpiq
the LED keeps blinking and nothing answers after a firmware update the bootloader has no valid firmware, or its CRC does not match after an upload with the programming adapter: flash again through the bootloader, see Updating through the bootloader

Motor GUI

Symptom Check
the browser offers no port a Chromium-based browser (Chrome, Edge, Brave, Opera); Firefox and Safari have no Web Serial
the port is listed but will not open another program holds it: a terminal, PlatformIO's monitor, the Arduino serial monitor
the port opens, nothing appears the driver's power; TX and RX crossed on a non-Source adapter; the baud rate on a non-Source adapter (256000)
No connection on CAN the CANvas adapter's port; the bus termination; the node ID of the driver; 1 Mbit/s
the calibration does not start calibration runs over the serial connection only, not over CAN
Unsaved changes after a power cycle the settings were not saved to the driver; Save writes them
the firmware update finds no bootloader power-cycle the driver while the GUI scans, to catch the bootloader's 2 s window. A driver with firmware 103 or older from the main branch has no bootloader: Installing the bootloader on an older board

Calibration

The messages and their causes are in Motor parameters and calibration. The ones that come back most:

Symptom Cause
Magnet test: Failed magnet too far, axially magnetised, or missing
the motor wobbles left and right during calibration one coil is not connected
the motor does not move in the open-loop step a coil open or not soldered; calibration then fails at the next step with Phase order is wrong!
Phase order is wrong! the motor did not respond to the commutation check; wiring, current limit, magnet
calibration succeeds, the motor then runs badly or in the wrong direction the magnet slipped on the shaft; glue it and calibrate again
calibration succeeds but the LED stays on and #Error shows nothing should not happen with firmware 106 and newer, which replaces a damaged configuration block with the defaults at power-up; if #Info shows -1: #Default, parameters, calibrate again

The motor

Symptom Cause
crunching or whining at speed the current limit or the current loop gains too high; lower #Ilim, lower #Cbw and calibrate again, or lower #Kpiq
humming, oscillating at rest #Kpv or #Kpp too high; see Current limit and loop tuning
weak torque #Ilim low; the supply's current limit; the wrong #R/#L (the computed current gains are off)
the motor is hot normal for a stepper at its rated current; lower #Ilim, enable the thermistor
it stops with a Vbus error when decelerating the supply cannot absorb the returned energy; a different supply, or a brake resistor
it stops with a velocity error the speed passed 30,000,000 ticks/s, a fixed threshold that #Vlimit does not change: a runaway, so check the magnet and the calibration
it loses position with a load that is a torque limit: a stepper under FOC does not lose steps, it falls behind; raise #Ilim within the motor's rating, or more motor
it holds position with a sawtooth noise the position loop gain; the magnet distance

Low-quality motors

Motors with visibly bad windings, an uneven back-EMF or a resistance that differs between the two coils calibrate poorly and run rough. The tested motors are known good.

The magnet and the encoder

  • The distance is 1 mm. "Magnet Good" from the magnet test does not mean the distance is right, only that the field is strong enough.
  • A magnet touching the chip can destroy the microcontroller; a magnet too far gives a noisy, wrong position.
  • The magnet must be diametrically magnetised and centred on the shaft.

The driver gets hot or shuts down

The firmware does not monitor the driver stage: if the stage stops on its own, for heat or a short, the motor loses torque and no error is reported. Lower the current limit, give the board airflow, check the motor leads for a short. Near 2.8 A the driver needs cooling.

After a firmware update

#Info shows the new release. If the values look wrong or the LED stays on: #Default, enter the motor parameters, #Cal, #Save. A release note says when an update clears the calibration.

Getting help

Support says where to ask and what to include; #Info's output is the first thing.

Comments


Found a mistake on this page? Edit it on GitHub · Report it · Get help · This page as Markdown · llms.txt · The whole manual as PDF