Defaults

The settings of the firmware at the release this site describes: their start values in common.h, and what EEPROM.cpp does with each.

  • Start value: the value in common.h. A setting the EEPROM does not keep starts from it at every power-up. A kept setting is replaced at power-up by the value in the EEPROM, so its start value is only seen before that.
  • After #Default: what #Default writes to the EEPROM and loads; — means #Default does not change it.
  • Kept by #Save: whether #Save (Send_Save_config) stores it, so that it survives a power cycle.

Internal state (error flags, counters, calibration steps, scratch variables) is left out; the error flags are in Errors and LED states.

Variable Start value After #Default Kept by #Save Firmware comment
SERIAL_NUMBER 1 111 in the EEPROM, not read back written, not read back
HARDWARE_VERSION 1 1 yes Version of the Spectral BLDC driver PCB
BATCH_DATE 1 125 yes Date the batch was produced
SOFTWARE_VERSION 1 108 no: set by the firmware Software release
I_AM_GRIPPER 1 0 yes Is motor controller gripper (1) or not (0)
LED_ON_OFF 1 1 yes Use LED for status indication
theta_offset 0.0f 0 yes will be determined at calibration
pole_pairs 50 0 yes Number of pole pairs of your Stepper motor
current_control_bandwidth 500 — no default 200 HZ; Will set PI gains for Q and D current loops based on phase resistance
DIR_ 1 0 yes When looking at the magnetic encoder counter-clockwise is POSITIVE rotation.
Phase_order 2 0 yes
commutation_dir 1 1 yes +1 or -1, auto-detected at calibration so +Iq/+velocity/+rotation map to +encoder rotation
Thermistor_on_off 0 0 yes Are we taking termistor mesurements? 0 is off, 1 is on
Resistance 0 0 yes Resistance of SINGLE PHASE of your BLDC motor
Total_Resistance 0 0 yes = 2 * Resistance + 2 * R_sense + 2 *Rdson
Inductance 0 0 yes Inductance of SINGLE PHASE of your BLDC motor
Kt 0 0 yes Torque constant of your BLDC motor
flux_linkage 0 0 yes Flux linkage of your BLDC motor
KV 0 0 yes
Max_temperature 75 75 yes Max temperature in degrees
Min_temperature -20 — no Min temperature in degrees
Max_Vbus 29500 29000 yes Max vbus voltage in mV
Min_Vbus 9000 — no Min vbus voltage in mV
watchdog_time_ms 0 0 yes
watchdog_action 0 0 yes Hold position, Idle, brake
Heartbeat_rate_ms 0 0 yes Motor controller will send data every Heartbeat_rate_ms
Calibrated 1 0 yes 0 if motor is not calibrated, 1 if it is calibrated
Resistance_calc_voltage 1000 — no Voltage used to calculate resistance //1000
Calibration_power 12 — no Max power that can dissipate during inductance test.
Open_loop_voltage 5000 — no Voltage to use when spinning the motor open loop. In mV
Open_loop_speed 20.0 — no Speed to be used when spinning the motor open loop. In RAD/s
Phase_voltage 5000 — no Max voltage to be used during Kv calculation
cyclic_period 0 — no We send messages every cyclic_period
CAN_ID 0 0 yes CAN id of THIS motor driver! No 2 motor drivers can share the same ID.
brake_coast 1 — no 1 is brake 0 is coast
trigger_value 0 — no 0=low level, 1=high level, 2=any edge
calibration_offset_current 500 — no
microstep 16 — no
gosteps 0 — no
step_interval 1000 — no step interval in microseconds
Voltage_limit 6000 6000 yes Voltage limit for Ud and Uq voltages. If 0 value of controller.VBUS_mV will be used
Reset_integral_accumulator 0 0 yes
Kp_p 5 5 yes
Position_setpoint 0 — no
Kp_v 0.007 0.007 yes basic values that work for most motors but not optimal
Ki_v 0.0005 0.0005 yes basic values that work for most motors but not optimal
Feedforward_speed 0 — no
Velocity_setpoint 0 — no -1.5
Velocity_limit 800000 800000 yes Clamp integrals to this [TICKS/s]
Velocity_limit_error 30000000 — no [TICKS/s] ; Velocity when we will report error / For stepper speed runout is around 250 nfo000
Kp_id 7 7 yes motor1
Ki_id 3 3 yes motor1
Id_setpoint 0 — no
Kp_iq 3 3 yes motor1
Ki_iq 0.3 0.3 yes motor1
Iq_current_limit 1700 1700 yes
Id_current_limit 0 0 yes
Feedforward_current 0 — no
KD 0.0028 0.0028 yes [Nm*s/rad]
KP 0.1400 0.1400 yes [Nm/rad]
Uq_setpoint 0 — no
Ud_setpoint 0 — no
position_setpoint 0 — no
speed_setpoint 50 — no
current_setpoint 400 — no
action_status 0 — no -0 Stopped(or performing activation /automatic release).
activated 0 — no
release_direction 0 — no
estop_status 0 — no