Skip to content

Getting started

Where to buy

You can buy a STEPFOC starter kit or a single STEPFOC driver in the Source Robotics shop.

  1. Diametrically magnetized magnet
  2. Stepper motor; see the tested motors
  3. Programming adapter
  4. Serial adapter
  5. CAN adapter
  6. Thermistor
  7. CAN wires and power wires

Hardware setup

Mounting PCB to Motor

Some hardware considerations:

  • Distance between motor encoder and magnet should be around 1 mm.
  • Hole spacing of STEPFOC is 31 mm (NEMA 17)

STEPFOC MAGNET

Electrical connections

Reversing the polarity on DC+ and DC- will destroy the board.

STEPFOC CONN

  1. Solder the motor phases to A+, A-, B+, B-: one coil of the stepper to A+ and A-, the other coil to B+ and B-. Find the two coils with a multimeter (the two wires of a coil have a few ohms between them, the two coils have no connection). Keep the wires long enough to swap them: if calibration reports a wrong phase order, swap A+ and A-, which reverses the direction of that coil.
  2. Connect motor power to one of the Power connectors terminals
  3. If you are using UART comms. Connect Uart adapter to UART connector
  4. If you are using thermistor, connect it to Thermistor connector
  5. If you are using CAN comms. Connect CAN adapter to one of CAN connectors
  6. When uploading code connect JTAG adapter to JTAG connector

Cable orientation

ALL cables used for daisy chain (CAN and power) need to to follow orientation as shown on the image below! Failing to follow that will destroy your motor controller! All correct cables can be bought here: https://source-robotics.com/pages/connectors-and-cables

Orientation

Connecting multiple motors (daisy chaining)

Multiple STEPFOC stepper drivers or Spectral BLDC drivers and nodes can be connected to single CAN bus using daisy-chaining. First and last nodes on can bus should have termination resistors. You can flip the CAN switch to "ON" position to enable termination resistor.

Power connectors can handle max 4 A DC. It is recommended to have at most 6 motor controllers (STEPFOC or Spectral micro) in one daisy chain.

Daisy chain

Thermistor connection

Solder the thermistor like shown in the image.

Thermistor is disabled by default. To enable it use command #Term 1

STEPFOC THERMISTOR

Thermistor needs to be placed on the housing of the stepper motor. Another option is remove one of the 4 stepper screws on the bottom and place thermistor inside that hole. Apply thermal cement on the thermistor to secure it in place and improve thermal conductivity.

Status

Normal operation Calibration Error mode
3 short flashed and a pause

Normal

Flashing every 0.5 seconds

Calib

Solid LED, no flashing.

Error2

If you have STEPFOC firmware uploaded on your STEPFOC, LEDs will be in one of 3 states.

STEPFOC controllers come PRELOADED with STEPFOC firmware

  • Normal operation is when motor controller has no active errors and is calibrated
  • Error mode is active if any error on the motor driver is active. List of possible errors:
    1. Temperature error
    2. Drv error
    3. Encoder error
    4. Vbus error
    5. Velocity error
    6. Current error
    7. Not calibrated
    8. Received ESTOP
    9. Watchdog error
  • Calibration will flash when in calibration routine

What next?