Gains and limits

Command Kind Argument What it does Response
#Vlim Set/Get int: voltage in mV The voltage limit of the current loops (Ud and Uq); 0 means use the supply voltage. the current limit in mV
#Vlimit Set/Get int: speed in encoder ticks/s The speed limit: the speed the position loop may command, and the largest velocity setpoint. (The velocity integrator is clamped to the current limit.) the current limit
#Kpp Set/Get float: gain Kp of the position loop. the current value
#KP Set/Get float: gain KP of the impedance (PD) loop. the current value
#KD Set/Get float: gain KD of the impedance (PD) loop. the current value
#Kpv Set/Get float: gain Kp of the velocity loop. the current value
#Kpiq Set/Get float: gain Kp of the Iq current loop; also sets Kpid. the current value
#Kpid Set/Get float: gain Kp of the Id current loop. the current value
#Kiv Set/Get float: gain Ki of the velocity loop. the current value
#Kiiq Set/Get float: gain Ki of the Iq current loop; also sets Kiid. the current value
#Kiid Set/Get float: gain Ki of the Id current loop. the current value
#Ilim Set/Get int: current in mA The Iq current limit. Set it to the rated phase current of your motor; the firmware clamps it to 2800 mA. the current limit
#Cbw Set/Get float: bandwidth in Hz The current loop bandwidth calibration uses to compute Kpiq and Kiiq. Not saved: 500 Hz after a power cycle. the bandwidth
#Rstint Set/Get int: 0 or 1 Whether the integral accumulators are reset on every new setpoint. the setting