Skip to content

Status and utility

#Save

Action

Writes the configuration to the EEPROM. Do it after calibration and after tuning.

Response: Save


#Reset

Action

Resets the driver. From firmware 104 the reset lands in the bootloader, which waits 2 s for a flashing host and then starts the firmware again.

Response: nothing


#Default

Action

Writes the factory defaults to the EEPROM and loads them: the calibration is erased (Not calibrated), the gripper flag, heartbeat and watchdog are cleared, the hardware version and batch date are set to 1 and 24092024, and 1111 is stored as the serial number; from firmware 109 also the tool id (0), the watchdog fallback, and the anti-cogging set, the encoder table, its trims and parameter 56 (cleared). From firmware 109 the CAN node ID is kept (0 only when no valid one is stored). Note the values first.

Response: Loaded default config!


#Pullconfig

Get

Prints the whole configuration on one line, for Motor GUI.

Response: the configuration


#Info

Action

Prints the driver's identity and the motor: hardware version, batch date, firmware version, ISR time, CAN ID, calibrated or not, temperature, Vbus, Dir, phase order, commutation direction, the speeds of the calibration spin, pole pairs, R, L, Kt and KV. From firmware 109 also the build (Build:, the git commit, with + when built with uncommitted changes), the Board ID (this board, from the chip's unique number; not the bootloader's board ID), the Calibration ID (new at every successful calibration), the CAN receive overruns and dropped transmits, the product, the current-sense zeros, the tool id, the watchdog and its fallback, settings block 2, the anti-cogging, and at the end the In force: section (see Status and diagnostics). The serial number is #SERNUM, the gains #Param, the errors #Error.

Response: the report


#Tone

Set/GetArgument f,mA[,ms], or offEnters position mode

A tone through the motor (see Sound): #Tone 440,250,1000 plays 440 Hz at a loudness of 250 mA for 1000 ms, on the axis parameter 82 picks. mA left out: 200; ms left out: 500; ms 0: until #Tone off. 20 Hz up to below 2500 Hz. It plays only while the driver holds or moves; from idle a calibrated driver first holds the position it is at (#Idle releases it). #Tone alone or #Tone off stops all sound. Added in firmware 109.

Response: Tone 440 Hz, 250 mA, 1000 ms; from idle first Holding the position while it plays (#Idle releases it); Tone: not played (…) when it cannot; Tone off


#Par

Set/GetArgument int: n, or n,value

Any parameter by its number (see Parameters and buffers): alone it lists every parameter, #Par 1 reads one, #Par 1,200 sets it (no spaces); a gain or limit (8-16, 20) takes a decimal, e.g. #Par 9,0.02 sets Kpv. Added in firmware 109.

Response: P<n> = <value>; refused: out of range, read only, not now, or unknown when the driver did not take it; P<n> unknown


#Tool

Set/GetArgument int: 0 to 255

The tool id: what the drive is built into, 0 none, 1 SSG-48, 11-33 MSG (tens = rail 1/2/3 = 100/150/200 mm, units = stepper 1/2/3 = 21.5/40/60 mm), 200-254 your own. The same as parameter 1. Kept by Save. Added in firmware 109.

Response: Tool ID: N, or Invalid tool id (0-255)


#WdFb

Set/GetArgument int list: time_ms,current_mA,speed_ticks_s,after_action

The watchdog fallback, four numbers at once without spaces, e.g. #WdFb 2000,0,1000,2: how long hold or descend runs, descend's current and speed cap, and what follows (0 legacy, 2 brake, 3 coast). The same as parameters 2 to 5, clamped the same way; fewer than four numbers change nothing. Kept by Save. Added in firmware 109.

Response: Watchdog fallback: … ms, … mA, … ticks/s, then …


#Product

ActionArgument nothing, or claim, clear

The product lock: prints this firmware and the board's stamp. claim stamps the board as this product (a repaired board, a motor the stamp rule misjudges), clear removes the stamp; power-cycle after either. Over UART only. Added in firmware 109.

Response: Firmware: Spectral Micro; board stamp: …


#Param

Get

Prints every gain of every loop.

Response: the gains


#Help

Action

Prints a short command reference. Added in firmware 106.

Response: the reference


#Error

Get

Prints which errors are active.

Response: No errors! or In error state!, then one line per active error (see Errors and LED states), and FAULT pin is LOW: the gate driver reports a fault while the driver stage's fault pin is active


#Clear

ActionEnters idle mode

Clears the errors and goes to idle. An error whose cause is still present comes straight back; a calibration error is cleared only by calibrating (or #Calibrated 1).

Response: Clear errors


#Mode

Get

Prints the control mode. In voltage-torque mode (#Uq) it prints nothing.

Response: Idle mode, Position control, Speed control, Current control, PD control, Open loop, Gripper mode, Gripper calib mode


#Vbus

Get

Prints the supply voltage.

Response: mV


#Vmax

Set/GetArgument int: voltage in mV

The supply voltage above which a Vbus error is raised: 29000 mV after #Default.

Response: Vmax in mV: N


#Temp

Get

Prints the thermistor temperature.

Response: °C, or Temp Off while the thermistor is disabled


#Term

Set/GetArgument int: 0 or 1

Enables the thermistor measurement and the temperature error (off by default). From firmware 110 also parameter 91.

Response: the setting


#Tlim

Set/GetArgument int: temperature in °C

The temperature at which the temperature error is raised; 75 by default.

Response: Temp limit N


#Iabc

Get

Prints the phase currents.

Response: Ia, Ib, Ic in mA


#PWM

Get

Prints the PWM duty values.

Response: the duties


#LED

Set/GetArgument int: 0 or 1

Turns the status LED on or off.

Response: the LED state


#CANID

Set/GetArgument int: 0 to 13

The CAN node ID. Use 0 to 13: the firmware accepts 14 and 15, but the bootloader reserves them and a driver on one of those cannot be updated over CAN. Kept over a power cycle after Save, which also copies it into the bootloader's board ID; from firmware 109 Default and a settings reset keep it too.

Response: the ID, or Invalid CAN ID


#SERNUM

Set/GetArgument int: number

The serial number. Save writes it to the EEPROM, but the firmware does not read it back at power-up: after a power cycle the driver reports 1.

Response: Serial number is: N


#Activate

Action

Sets the controller's activated flag (bit 6 of byte 1 of Send_Respond_State_of_Errors). It is not the gripper's activate bit, which #Gripact and Send_gripper_data_pack set.

Response: Controller activated


#Cyc

Set/GetArgument int: interval in ms (0 = off)

Sends position, speed and Iq on its own every interval: $ <position> <speed> <Iq>; for BetterSerialPlotter.

Response: Cyclic disabled for #Cyc without a number; #Cyc 0 stops the output without an answer


#Cyca

Set/GetArgument int: interval in ms (0 = off)

Like Cyc, in the Arduino plotter format Position:x,Speed:y,Iq:z.

Response: Cyclic disabled for #Cyca without a number; #Cyca 0 stops the output without an answer


Comments


Found a mistake on this page? Edit it on GitHub · Report it · Get help · This page as Markdown · llms.txt · The whole manual as PDF