Calibration and motor parameters

Command Kind Argument What it does Response
#R Set/Get float: resistance in Ω The phase resistance of the motor, measured by Cal; it can also be set by hand. the current value
#L Set/Get float: inductance in H The phase inductance of the motor, measured by Cal; it can also be set by hand. the current value
#Kt Set/Get float: Nm/A The torque constant, found by calibration. the current value
#KV Set/Get float: rpm/V The velocity constant, found by calibration. the current value
#Flux Set/Get float: Wb The flux linkage, found by calibration. Not reachable over UART: the parser accepts #flux (lowercase) but the handler expects Flux, so neither spelling works. the current value
#Cal Action Runs the calibration routine (see Calibration): it measures R and L, finds the pole pairs, the phase order and the angle offset, and measures Kt, KV and the flux linkage. the calibration log
#Offset Set/Get float: angle in rad The angle offset between encoder zero and electrical zero, found by calibration. the current value
#Iqoffset Set/Get int: current in mA The current used by the angle-offset search and the commutation check of Cal, 300 mA by default. Not saved. the current value
#Magnet Get Reads the encoder's magnet status. Magnet Good or Magnet Bad
#Dir Set/Get int: 0 or 1 The counting direction of the encoder, set by calibration (0 after #Default). the current value
#Phase Get Prints the phase order found by calibration. Phase order is: N
#Resv Set/Get int: voltage in mV The voltage the resistance test of Cal starts at; it rises until the power reaches Calpwr. Not saved. the current value
#Calpwr Set/Get float: power in W The power the resistance and inductance tests of Cal may dissipate in the motor. Not saved. the current value
#Openv Set/Get int: voltage in mV The voltage of the open-loop spin, in calibration and with Openloop. Not saved. the current value
#Opens Set/Get float: electrical speed in rad/s The speed of the open-loop spin in calibration; the same setting as the speed of #Openloop. the current value
#Vp Set/Get int: voltage in mV The voltage of the phase-order search in calibration. Not saved. the current value
#Calibrated Set/Get int: 0 or 1 The calibrated flag. #Calibrated 1 clears a calibration error without calibrating; the motor may still be uncalibrated. the flag
#PP Set/Get int: pole pairs The motor's pole pairs, found by Cal; they can also be set by hand. the current value