Gripper mode¶
A driver can run a gripper instead of a joint: the same board, with a state machine that moves a jaw to a position between open and closed, at a speed, with a current limit that becomes the grip force, and that reports when it holds something. The MSG gripper is built on STEPFOC this way.
Turning it on¶
#Default clears the flag again. A driver in gripper mode still answers every other command; the gripper
commands only work with the flag set.
Calibrating the gripper¶
After every power-up the gripper has to find its end stops: #Gripcal or Send_gripper_calibrate. The jaws open
until they stop, then close until they stop, slowly and at 500 mA; the positions become 0 (open) and 255 (closed).
The driver prints nothing when it is done.
If it has not found both end stops within about 24 s it gives up, and
the gripper stays uncalibrated. Check the result with #Gripinfo (Gripper calibrated is: 1) or the
gripper_calibrated bit of Respond_Gripper_data_pack: a move is carried out only once the gripper is calibrated.
The motor itself must be calibrated (#Cal) and saved before that, once.
While the gripper calibrates, send only empty status polls. A 5-byte Send_gripper_data_pack, Send_Clear_Error
or #Clear stops the calibration without a message, and the next one then starts part way through, where the
stopped one left off: switch the driver off and on before you calibrate again
(known issue KI-7).
Moving¶
Over UART:
#Gripvel 100 speed, 0 to 255
#Gripcur 400 current limit of the move in mA, the grip force
#Grippos 200 go to position 200 (0 open, 255 closed); also activates the gripper
Over CAN, Send_gripper_data_pack carries position, speed and current in one frame with the activate and action bits; the driver answers with Respond_Gripper_data_pack: the position, the measured current, whether it is moving, and the object detection:
| Object detection | Meaning |
|---|---|
| 0 | moving |
| 1 | an object was detected while closing: the jaws stopped on it and hold it with the current limit |
| 2 | an object was detected while opening |
| 3 | the position was reached |
An empty Send_gripper_data_pack (0 bytes) only asks for the state. The answer to a 5-byte command goes out before the driver acts on it, so its object detection and error bits are still those of the moment before (KI-6); the answers to the next frames show the new move.
The action bit in the answer is a copy of the last command's action bit and stays 1 after the move ends (KI-8): the object detection tells when it has ended.
Send_gripper_data_pack's E-stop bit raises the
gripper E-stop error; #Gripstop 1 does the same over UART. The error stays: while the E-stop bit is 1 the driver
raises it again on every control cycle, and #Error prints only In error state!. To recover, clear the bit
(#Gripstop 0, or a Send_gripper_data_pack with the bit 0), then #Clear or Send_Clear_Error.
Current
From firmware 109 a gripper move uses the magnitude of the current you give it, at most the driver's 2800 mA; 108 and older used it as sent. The safe range depends on the gripper's mechanics and motor; the gripper's manual gives it.
Where the details are¶
The bytes of the two gripper frames are in the CAN reference, the UART commands in the UART reference.