Errors and recovery

When the driver inside the gripper detects a fault it stops the motor, goes to idle and sets the error bit in every CAN frame it sends. The grip is released: an idle motor holds nothing beyond the mechanism's friction.

Seeing the error

  • The error bit of every answer's identifier: 1 while any error is active.
  • Respond_Gripper_data_pack carries the three gripper error bits: temperature, timeout, E-stop.
  • Send_Respond_State_of_Errors returns every flag of the driver, which is where the other causes show.
  • Motor GUI shows the errors in its gripper panel; #Error over UART prints them.

The errors

Error Reported in Cause What to do
Temperature the gripper's temperature bit the thermistor in the windings reads more than 75 °C (#Tlim) let the motor cool; hold with less current
Timeout the gripper's timeout bit the driver's CAN watchdog ran out: no valid frame within the time set by Send_Watchdog the host stopped sending; fix the host, then clear
E-stop the gripper's E-stop bit a move command with the E-stop bit set, or #Gripstop 1 send a command with the bit at 0 (or #Gripstop 0), then clear: while the last command's bit is 1, a clear does not hold
Not calibrated (motor) State_of_Errors, #Error the driver's own motor calibration is missing: a self-built gripper before Driver configuration, or after #Default calibrate the motor
Vbus State_of_Errors the supply is below 9 V or above the driver's #Vmax limit, 29 V after #Default the supply, the cable
Encoder State_of_Errors the driver's encoder does not see its magnet the magnet on the motor shaft (a self-built gripper)
Driver State_of_Errors the driver stage's own protection tripped: overcurrent, overtemperature lower the current; check the motor leads
Velocity State_of_Errors the motor exceeded the driver's speed limit unlikely in a gripper; clear
Driver E-stop State_of_Errors Send_ESTOP was received clear

A gripper that is not gripper-calibrated is not in error: it just refuses moves until Send_gripper_calibrate has found the end stops.

Clearing

Send_Clear_Error, Clear in the GUI or #Clear clears every flag, the gripper's E-stop included, and goes to idle. An error whose cause is still present comes straight back: a hot motor, a supply that is still low.

The gripper's E-stop counts as such a cause while the E-stop bit of the last gripper command is 1: the driver raises the error again at every cycle. So after an E-stop, first send a gripper command with the E-stop bit at 0 and the action bit at 0 (or #Gripstop 0 over UART), then clear. The next command with the action bit set moves the gripper again.

After clearing, the gripper is idle and still calibrated and activated; the next move command moves it. A clear sent while the gripper calibration runs ends the calibration, and the gripper stays uncalibrated.

When the gripper does not answer

  • No answer at all: the supply, the cable (and its pinout), the bus termination (about 60 Ω across CANH and CANL with everything unpowered), 1 Mbit/s on the adapter, the node ID.
  • Answers but does not move: not calibrated, not activated, an error active, or the action bit at 0.
  • Moves to one end during calibration and stops there: the other end stop is blocked, or the mechanism is too stiff for the calibration's 500 mA; after 30 seconds the routine gives up.

Troubleshooting goes through the symptoms one by one.