Driver setup

The driver commands a self-built gripper is configured with; Driver configuration is the procedure.

Command Kind Argument What it does Response
#Kpiq Set/Get float: gain Kp of the Iq current loop; also sets Kpid. the current value
#Kiiq Set/Get float: gain Ki of the Iq current loop; also sets Kiid. the current value
#R Set/Get float: resistance in Ω The phase resistance of the motor (one coil). STEPFOC does not measure it; enter the datasheet value before Cal. the current value
#L Set/Get float: inductance in H The phase inductance of the motor (one coil); enter the datasheet value before Cal. the current value
#Kt Set/Get float: Nm/A The torque constant, found by calibration. the current value
#Cal Action Runs the driver's motor calibration (see Driver configuration): enter PP, R and L first, with the pinion not yet in the rack. the calibration log
#Save Action Writes the configuration to the EEPROM. Do it after calibration and after tuning. Save
#Ilim Set/Get int: current in mA The driver's Iq current limit outside gripper mode; the firmware clamps it to 2800 mA. Gripper moves use Gripcur instead. the current limit
#Tlim Set/Get int: temperature in °C The temperature at which the temperature error is raised; 75 by default. Temp limit N
#Default Action Writes the factory defaults to the EEPROM, including the serial number, hardware version and batch date, and clears the gripper flag, heartbeat and watchdog. Back those up first. Loaded default config!
#Term Set/Get int: 0 or 1 Enables the thermistor measurement and the temperature error (off by default). the setting
#Cbw Set/Get float: bandwidth in Hz The current loop bandwidth calibration uses to compute Kpiq and Kiiq. the bandwidth
#CANID Set/Get int: 0 to 13 The CAN node ID. Use 0 to 13: the firmware accepts 14 and 15, but the bootloader reserves them and a driver on one of those cannot be updated over CAN. Save keeps it over a power cycle and also writes it into the bootloader's board ID. the ID, or Invalid CAN ID
#PP Set/Get int: pole pairs The motor's pole pairs: 50 for a 1.8° stepper, 75 for 1.2°, 100 for 0.9°, 125 for 0.72°. Calibration accepts only these values. the current value